Error description
MSMQ Adapter RETRIEVE operation fails with Deadletter queue after upgrading to 5020603_13
Local fix
STRRTC - L3REQ-1019 SBN / SBN Circumvention - NONE
Problem summary
Users Affected: All Problem Description: MSMQ Adapter RETRIEVE operation fails with Deadletter queue after upgrading to 5020603_13. Platforms Affected: All
Problem conclusion
Resolution Summary: A code fix is provided. Per 526x release notes, the 526x IBM Sterling Integrator is compatible with 5242 prime component, however if the "FormatName" is used in the "QueuePathName" to access a MSMQ queue, we see exceptions as the 5242 primecomponent expects not to append the "FormatName" in the target "QueuePathName". Provided a code fix to handle this scenario. Delivered in: 5020603_15 6000005 5020605_3
Temporary fix
Comments
APAR Information
APAR number
IT32794
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
526
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-05-07
Closed date
2020-06-11
Last modified date
2020-10-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
[{"Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.6"}]
Document Information
Modified date:
14 October 2020