Direct link to fix
APAR status
Closed as program error.
Error description
The Flat File Adapter can't process event files that have read-only permission after you upgrade to 7.5.0.5 interim fix 14 or 7.5.0.5 interim fix 15. PRODUCTS AFFECTED IBM Business Automation Workflow IBM WebSphere Adapter for Flat Files
Local fix
Give write permission on the event files
Problem summary
The Flat File Adapter can't process event files that have read-only permission after you upgrade to 7.5.0.5 interim fix 14 or 7.5.0.5 interim fix 15.
Problem conclusion
A fix that continues processing event files with read-only permission is included in IBM WebSphere Adapter for Flat Files 7.5.0.5 IF16.
Temporary fix
Not applicable.
Comments
APAR Information
APAR number
JR62117
Reported component name
WEBS ADPT FLAT
Reported component ID
5724L7800
Reported release
750
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-03-12
Closed date
2020-04-15
Last modified date
2020-04-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBS ADPT FLAT
Fixed component ID
5724L7800
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSMKUK","label":"WebSphere Adapters Family"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"750","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
29 June 2020