Error description

  • An HPC004 abend can occur if HCPALF has set FRMOWNED off before
    acquiring the UFO lock and HCPHPC acquires the UFO lock and is
    attempting to use the same FRMTE.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users that are overcommited and using lots   *
    *                 of PGMBKs are affected.                      *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION: APPLY PTF                                    *
    ****************************************************************
    In rare timing situations, both HCPALF and HCPHPC could be
    attempting serialization on the same FRMTE. If HCPALF first
    turns off FRMOWNED and then attempts to get the UFO lock and
    HCPHPC gets the lock first, then HCPHPC will see FRMOWNED OFF
    and abend before HCPALF fails and turns FRMOWNED back on.
    

Problem conclusion

  • The serialization in HCPALF was changed to acquire the UFO lock
    first before turning off FRMOWNED. This stops HCPHPC from
    seeing FRMOWNED OFF if they are both going after the same FRMTE.
    

Temporary fix

  • FOR RELEASE VM/ESA CP/ESA R640 :
    PREREQ: NONE
    CO-REQ: NONE
    IF-REQ: NONE
    FOR RELEASE VM/ESACP/ESAR710 :
    PREREQ: NONE
    CO-REQ: NONE
    IF-REQ: NONE
    

Comments

APAR Information

  • APAR number

    VM66397

  • Reported component name

    VM CP

  • Reported component ID

    568411202

  • Reported release

    640

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-06-02

  • Closed date

    2020-07-09

  • Last modified date

    2021-06-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UM35687 UM35688

Modules/Macros

  • HCPALF
    

Fix information

  • Fixed component name

    VM CP

  • Fixed component ID

    568411202

Applicable component levels

  • R640 PSY UM35687

       UP20/07/22 I 1000

  • R710 PSY UM35688

       UP20/07/22 P 2101