IBM Support

IT32159: HIGH CPU AFTER A WEBSPHERE JMS CONNECTION ERROR

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The user observes DataPower might face high CPU in case of
    continuous Websphere JMS connection errors.
    In particular, this was observed in a Strict-Message-Order
    usecase on a secondary instance that was blocked from accessing
    the target SI Bus JMS queue as expected.
    It seems some indefinite retry drives the high CPU.
    

Local fix

Problem summary

  • For DataPower users who use WebSphere JMS and have enabled the
    "Strict Message Ordering" for the corresponding JMS
    Destinations, if there are more than two DataPower appliances
    trying to make subscriptions to the same JMS Destinations, then
    DataPower might be hanging on the retrying and cause high CPU
    usage issue. When the "Strict Message Ordering" is enabled in
    JMS server, it allows only one JMS client for one JMS
    Destination at the same time.
    

Problem conclusion

Temporary fix

  • Avoid setting more than one DPs to connect to one JMS
    Destination at the same time.
    

Comments

APAR Information

  • APAR number

    IT32159

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    18X

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-03-12

  • Closed date

    2020-05-04

  • Last modified date

    2020-05-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R18X PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
08 June 2021