Error description
Description : If a Situation includes many predicates in its formula that involve large attribute columns, the literal pool of the associated Filter Object can exceed 32k. When this occurs, the code attempts to shrink the pool by optimising the memory utilisation. In the process, the code was incorrectly calculating the memory required to contain the literal pool which resulted in a memory overlay leading to corruption and a subsequent access violation. Solution : The code was changed to correctly compute the amount of memory required to contain the literal pool.
Local fix
Problem summary
If a Situation includes many predicates in its formula that involve large attribute columns, the literal pool of the associated Filter Object can exceed 32k. When this occurs, the code attempts to shrink the pool by optimising the memory utilisation. In the process, the code was incorrectly calculating the memory required to contain the literal pool which resulted in a memory overlay leading to corruption and a subsequent access violation. A TEMS may crash when a Situation is started.
Problem conclusion
The code was changed to correctly compute the amount of memory required to contain the literal pool. The fix for this APAR is contained in the following maintenance packages: | service pack | 6.3.0.7-TIV-ITM-SP0006
Temporary fix
Comments
APAR Information
APAR number
IJ25289
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-06-01
Closed date
2020-12-14
Last modified date
2020-12-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMS
Fixed component ID
5724C04MS
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
08 March 2023