IBM Support

"MSR-UI-0001 An error occurred while generating the UI interface" when browsing the Lineage Property of the Package in Cognos Analytics

Troubleshooting


Problem

MSR-UI-0001 An error occurred while generating the UI interface.
2

Resolving The Problem

1.Stop Cognos Analytics services.

2. Back up Folders

<cognos_home>\Logs\*,

<cognos_home>\temp\*,

<cognos_home>\javasharedresources\*,

<cognos_home>\wlp\usr\servers\cognosserver\workarea\*

<cognos_home>\wlp\usr\servers\dataset-service\workarea\*

3. Remove all files from the folders. (i.e. keep the each directory, but delete everything in it, including subdirectories)

4. Restart Cognos Analytics services.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTSF6","label":"IBM Cognos Analytics"},"ARM Category":[{"code":"a8m500000008d6oAAA","label":"Modeling"}],"ARM Case Number":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Version(s)","Line of Business":{"code":"LOB10","label":"Data and AI"}}]