Error description
When a COBOL V5+ program is loaded using the CEEFETCH MACRO, the address of the routine returned by the macro is not a proper function descriptor. Using this address to call the program may result in an 0C4 ABEND.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V5 and V6 with * * Assembler programs that load and call COBOL * * programs using CEEFETCH. * * * **************************************************************** * PROBLEM DESCRIPTION: Runtime ABEND 0C4: When an Enterprise * * COBOL V5+ program is loaded and called * * using the CEEFETCH MACRO, the program * * may fail with an 0C4 ABEND. * * * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * * * **************************************************************** The Enterprise COBOL V5+ runtime failed to support LE event 40, when asked to provide a function pointer to call the COBOL V5+ program with. FIXCAT keyword: COB0501T/K COB0502T/K COB0601T/K
Problem conclusion
The Enterprise COBOL runtime is corrected to support LE event 40.
Temporary fix
Comments
APAR Information
APAR number
PI70080
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
790
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-10-03
Closed date
2016-10-14
Last modified date
2016-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI41673 UI41674
Modules/Macros
HLE77A0J HLE7790 IGZCER4 IGZCEV4 IGZLLIBV IGZXAPI IGZXDMR IGZXD24 IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2 IGZXTMSG
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
Fix is available