A fix is available
APAR status
Closed as program error.
Error description
The ABEND issue with error code U4088 reason x'63' at QSAM file operation may occur when the dataset is RECFM=U and it is a dataset with multi-volumes that is eligible for Large Block Inerface processing.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Enterprise COBOL V5 users running programs * * that have QSAM files defined with RECFM=U; * * and that are eligible for LBI (Large Block * * Interface) processing; and have multiple * * volumes. * * * **************************************************************** * PROBLEM DESCRIPTION: ABEND U4088 reason code 63 during QSAM * * * **************************************************************** * RECOMMENDATION: * **************************************************************** In the I/O exit routine that handles end of volume processing for the COBOL runtime, it uses the save area prepared by the I/O verbs routines for RECFM=U with LBI to acquire LE stack space. The save area was incorrectly prepared which cause the ABEND.
Problem conclusion
The runtime library was corrected so that QSAM I/O verbs for datasets with RECFM=U, LBI, and multiple volumes would no longer cause a U4088, reason 63 ABEND during end of volume processing.
Temporary fix
Comments
APAR Information
APAR number
PI36810
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
780
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-03-11
Closed date
2015-03-18
Last modified date
2015-05-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGZXLPKA
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
Fix is available