A fix is available
APAR status
Closed as program error.
Error description
UNSTRING statement reads past the end of sending field causing false matches with DELIMITER value. UNSTRING may put one extra byte into the DELIMITER field.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V5 and later * * releases who are using UNSTRING statement. * **************************************************************** * PROBLEM DESCRIPTION: The COBOL runtime UNSTRING routine * * does one extra delimiter check beyond * * the end of the sending field, causing * * incorrect UNSTRING result. * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** During UNSTRING processing, the COBOL runtime fails to check for the remaining length of the sending field, and uses dirty byte values following the end of the field to do one extra delimiter comparison before stopping. This could lead to erroneous UNSTRING result.
Problem conclusion
The COBOL Runtime is corrected to stop properly at the end of the sending field when the remaining field length is too short to do delimiter comparison.
Temporary fix
Comments
APAR Information
APAR number
PH09481
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7B0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-03-07
Closed date
2019-03-14
Last modified date
2019-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGZCEV4 IGZCMGEN IGZCMGUE IGZLLIBV IGZXAPI IGZXCDA IGZXD24 IGZXDMR IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
R7B0 PSY UI61879
UP19/03/29 P F903
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date: