Error description
IGZ0033S message when a COBOL V5+ program dynamically calls a COBOL pre-V5+ program which enables RTEREUS(ON), the callee is incorrectly marked as AMODE(24) even though the callee is loaded above the line. IGZ0033S An attempt was made to pass a parameter address above 16 megabytes to AMODE(24) program
Local fix
None. Apply PTF
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 5.1 and later * * releases compiling and running AMODE(31) * * programs with runtime option RTEREUS(ON) * * that do dynamic calls to AMODE(31) COBOL * * programs prior to COBOL 5.1. * **************************************************************** * PROBLEM DESCRIPTION: The called subprogram may incorrectly * * terminate with an IGZ0033S message. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The AMODE(31) COBOL subprogram prior to COBOL 5.1 running under RTEREUS(ON) is incorrectly marked as AMODE(24) by the COBOL Runtime. When the COBOL subprogram is also the first one invoked under the RTEREUS(ON) environment and, later is dynamically called a second time with parameters by an AMODE(31) COBOL 5.1 and later dynamic caller, the diagnostic message IGZ0033S is issued due to the 31-bit parameters.
Problem conclusion
The COBOL Runtime was changed to correctly mark AMODE(31) subprograms running under RTEREUS(ON) as AMODE(31).
Temporary fix
Comments
APAR Information
APAR number
PI93662
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7B0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-02-12
Closed date
2018-02-13
Last modified date
2018-03-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGZCEV4 IGZCMGEN IGZCMGUE IGZLLIBV IGZXAPI IGZXBST IGZXBST1 IGZXBST2 IGZXBST3 IGZXCDA IGZXD24 IGZXDMR IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
R7B0 PSY UI53820
UP18/02/28 P F802
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 December 2020