Fixes are available
Rational Developer for System z Fix Pack 1 (9.1.1.1) for 9.1.1.
Rational Developer for System z Fix Pack 1 (9.1.1.2) for 9.1.1.
Rational Developer for System z Fix Pack 1 (9.1.1.3) for 9.1.1.
Rational Developer for System z Interim Fix 1 for 9.1.1.3
Rational Developer for System z Fix Pack 1 (9.1.1.4) for 9.1.1.
Rational Developer for System z Fix Pack 1 (9.1.1.5) for 9.1.1.
Rational Developer for System z Fix Pack 1 (9.1.1.6) for 9.1.1.
Rational Developer for System z Fix Pack 1 (9.1.1.7) for 9.1.1.
Rational Developer for System z Fix Pack 1 (9.1.1.8) for 9.1.1
Rational Developer for System z Fix Pack 9 (9.1.1.9) for 9.1.1
APAR status
Closed as program error.
Error description
In Rational Developer for System z (RDz) 9.1, using ISPF editor profile will set tabs to column 1 editing a .asm file in LPEX editor. When a user adds the set tabs command in the initial LPEX commands field in HLAsm Parser preference dialog (Window > Preferences > LPEX Editor > System z LPEX Editor > HLAsm Parser), and then edits a .asm file, the tabs values specified in the initial LPEX command will not be honoured and the tab button would not move beyond column 1 in the LPEX editor.
Local fix
Use the default eclipse editor profile instead of the ISPF profile and set the desired tabs command
Problem summary
ISPF profile overrides the HLASM parser's tab setting.
Problem conclusion
ISPF profile no longer enforces a tab setting. The problem listed in this APAR has been resolved with IBM Rational Developer for System z V9.1.1.1 Fix Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PI30741
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-12-02
Closed date
2015-03-24
Last modified date
2015-03-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R911 PSY
UP
Document Information
Modified date:
17 October 2021