A fix is available
APAR status
Closed as program error.
Error description
Rational Developer for System z - RDz - V8.5.1.4 In RDz, running a TSO command through APPC may fail with the error: "ERR: Receive of Host IP, port" if: - the APPC transaction uses a passticket generated outside RDz (by a custom plugin for example) - and the APPC transaction has timed out - and the passticket has timed out Re-creation steps: For instance, use the following: 1- a custom plugin generates a passticket and pass it to RDz to automatically connect the user 2- in SDSF, cancel the APPC task for the connected user 3- wait 11 minutes (RACF timeout for passticket is 10 minutes) 4- In RDz client, open a TSO command shell and type a command (LU MYUSER). The following error is displayed: Error in RDZ client "Connection refused" 5- In RDz client, open a TSO command shell and type a command (LU MYUSER). The following error is displayed: Error in RDZ client "ERR: Receive of Host IP, port"
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: 01.All RDz users who connect to an APPC * * enabled RDz server * * 02.All RDz users * **************************************************************** * PROBLEM DESCRIPTION: 01.APPC command server in RDz server * * should use passtickets * * 02.The condition handler registered in * * the resource serialization logic * * sets the wrong result value. * **************************************************************** * RECOMMENDATION: * **************************************************************** 01.RDz server with APPC command server enabled assumes RDz client passes user id and password and the passed password should be valid while the client is connecting. If the passed password has a short life time like a passticket, when the password is expired, RDz server can not call APPC command server correctly and it causes errors. 02.Because a condition handler sets the wrong result value of 20, it is called repeatedly when an exception occurs while serializing a resource.
Problem conclusion
01.RDz server is updated not to expect client to pass password but to generate passticket internally. The APPLID for this passticket must be the partner-LU, and must be defined as _FEKFSCMD_PARTNER_LU_ variable in rsed.envvars. 02.The condition handler is updated to set the correct result value of 10 to be called just once when an exception occurs while serializing a resource.
Temporary fix
Comments
APAR Information
APAR number
PI26973
Reported component name
RD/Z HOST
Reported component ID
5724T0723
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-10-03
Closed date
2015-01-20
Last modified date
2015-02-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FEKDSI FEKFENVR FEKFLDSL FEKFMAIN FEKFMAI6 FEKFMINE FEKFTSO FEKFZOS
Fix information
Fixed component name
RD/Z HOST
Fixed component ID
5724T0723
Applicable component levels
R850 PSY UI24911
UP15/02/05 I 1000
Fix is available