Direct link to fix
APAR status
Closed as program error.
Error description
If you have a '\u2028' line or '\u2029' paragraph separator in a script or as step name in a service or process in the web IBM Process Designer, you can't open its editor. The browser console shows the following error: "{"status":"error","Data":{"status":"error","exceptionType":"com .ibm.bpm.wle.api.UnexpectedFailureException","errorNumber":"CWTB G0019E","errorMessage":"CWTBG0019E: Unexpected exception during execution. Exception information: 'non-hex digit on line 1, column 1427'.","errorMessageParameters":["non-hex digit on line 1, column 1427"],"programmersDetails":"non-hex digit on line 1, column 1427","responses":null,"errorData":null}}" PRODUCTS AFFECTED IBM Business Automation Workflow
Local fix
Problem summary
No additional information is available.
Problem conclusion
A fix is available or will be available that ensures the Service editor opens when a script or step name contains a line or paragraph separator.
Temporary fix
Comments
APAR Information
APAR number
JR61842
Reported component name
BUS AUTO WORKFL
Reported component ID
5737H4100
Reported release
J00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-12-20
Closed date
2020-04-28
Last modified date
2020-04-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BUS AUTO WORKFL
Fixed component ID
5737H4100
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS8JB4","label":"IBM Business Automation Workflow"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"19.0.0.1","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
22 June 2020