APAR status
Closed as program error.
Error description
IDz 14.2.2 z/OS Debugger Profile view with back-level connections for non-CICS profile adds extra & before IP address TEST(ALL,,PROMPT,TCPIP&&172.25.144.2%8001:*)
Local fix
Remove one &
Problem summary
**************************************************************** * USERS AFFECTED: * * All debug profile user interface users who are not using * * Debug Manager or Debug Profile Service. * **************************************************************** * PROBLEM DESCRIPTION: * * When Debug Profile Service and Debug Manager are not * * running, creating a non-CICS profile results in a TEST * * runtime option with two & (ampersands) after the TCPIP * * string. * * The following is incorrectly generated: * * TEST(,,,TCPIP&&5.5.5.5%8001:*) * * when it should be * * TEST(,,,TCPIP&5.5.5.5%8001:*) * * * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The debug profile user interface was modified to ensure a valid TEST runtime option is generated when neither Debug Manager nor Debug Profile Service are running. This issue is fixed in v14.2.3 of the following products: IBM Debug for z/OS IBM Developer for z/OS IBM Developer for z/OS Enterprise Edition
Temporary fix
Comments
APAR Information
APAR number
PH24380
Reported component name
DEV FOR Z/OS
Reported component ID
5724T0700
Reported release
E22
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-04-14
Closed date
2020-06-11
Last modified date
2020-06-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DEV FOR Z/OS
Fixed component ID
5724T0700
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSJK49","label":"IBM Developer for z Systems"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"E22","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 June 2020