Product Documentation
Abstract
The LogOutput TM1 TurboIntegrator function was added for TM1 version 10.2.2 but is not included in the documentation.
Content
LogOutput
This function writes a message to the tm1server.log file when an error of a specified severity level is encountered in a TurboIntegrator process.
To enable message logging from TurboIntegrator, you must add the TM1.TILogOutput debugger to the tm1-log.properties file and set the debugger to the desired level. For example, adding TM1.TILogOutput=DEBUG to tm1-log.properties enables logging for all severity levels. For details on the tm1-log.properties file, see http://www.ibm.com/support/knowledgecenter/SS9RXT_10.3.0/com.ibm.swg.ba.cognos.tm1_op.10.3.0.doc/c_configuringandenablinglogging_n160682.html%23ConfiguringandEnablingLogging_N160682
As with all TurboIntegrator function names, 'LogOutput' is a reserved word that should not be used as a variable name in TurboIntegrator processes.
Syntax:
LogOutput('SeverityLevel', 'MessageString');
Argument | Description |
SeverityLevel | The severity level that initiates logging to the tm1server.log file. Valid values for this argument are:
|
MessageString | The message you want to write to the tm1server.log file. The message string can be a string enclosed in single quotes or can be another TurboIntegrator function that returns a string. |
Examples:
LogOutput('WARN', 'TI process encountered a warning condition');
LogOutput('ERROR', TM1User() );
Was this topic helpful?
Document Information
Modified date:
17 June 2018
UID