A fix is available
APAR status
Closed as new function.
Error description
Enabling debug support for dynamic-length elementary items
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.3 whose COBOL * * programs contain dynamic-length elementary * * items and compile with the TEST option. * **************************************************************** * PROBLEM DESCRIPTION: This compiler error message is issued: * * IGYDS1539-W The "DYNAMIC LENGTH" * * clause is not supported when the * * TEST option is in effect. The * * "DYNAMIC LENGTH" clause was accepted. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** This PTF adds support for compiling programs with the TEST option that contain dynamic-length elementary items.
Problem conclusion
The compiler was updated to allow compiling programs that contain dynamic-length elementary items with the TEST option without encountering compile time warning message IGYDS1539-W.
Temporary fix
Comments
APAR Information
APAR number
PH22063
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-02-11
Closed date
2020-03-26
Last modified date
2020-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI68641 UI68642 UI68643 UI68644
Modules/Macros
IGY8RWRD IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI68641
UP20/04/01 P F003
R631 PSY UI68642
UP20/04/01 P F003
R632 PSY UI68643
UP20/04/01 P F003
R63H PSY UI68644
UP20/04/01 P F003
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023