Error description
After a restart of the Accelerator component (for example, triggered by reset, update, or reactivation of the LPAR), the "Accelerator component health status" reports that "Appliance data service" fails to start and the Accelerator is not able to process requests anymore.
Local fix
The issue happens because of an active try&buy license for Db2 Wh which expires three months after initial installation of the database. Re-install or "reset with wipe" enables the license for another three month (but data would be lost and reload required). In a remote maintenance session IDAA support can apply a correct (permanent) license file, especially for a system which is currently in failed state. IDAA 7.5.0.2 will contain a correct license file. We strongly recommend to upgrade to this maintenance level once available.
Problem summary
The try & buy license for Db2 Wh included in maintenance level 7.5.0 and 7.5.0.1 has been replaced with a regular license not expiring.
Problem conclusion
The issue has been fixed with maintenance level 7.5.0.2.
Temporary fix
Comments
APAR Information
APAR number
PH23674
Reported component name
ANYTCS ACCLTR Z
Reported component ID
5697DA700
Reported release
750
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-03-25
Closed date
2020-03-27
Last modified date
2020-03-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"750","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
25 March 2020