Error description

  • ABND = 0C6-00000006 and ABND = 0C1-00000001 in DB2 may occur
    due to incompatibility between Query Monitor and another
    monitoring product.
    .
    The other product issues a BAKR 0,R14 to create a linkage stack
    entry in DB2 GETPAGE processing and R14 picked up a wrong
    address.
    .
    This APAR adds code to tolerate this monitoring technique.
    

Local fix

  • Add OBJECTS(N) to the CQMPARMS parameter file ( recycle the CQM
    Collector to pickup the change ).
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Query Monitor                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND0C6-00000006 and ABEND0C1-00000001 *
    *                      in DB2                                  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    ABND = 0C6-00000006 and ABND = 0C1-00000001 in DB2 may occur
    due to incompatibility between Query Monitor and another
    monitoring product.
    The other product issues a BAKR 0,R14 to create a linkage stack
    entry in DB2 GETPAGE processing and R14 picked up a wrong
    address.
    

Problem conclusion

  • This APAR adds code to tolerate this monitoring technique.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI36826

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-03-11

  • Closed date

    2015-05-11

  • Last modified date

    2015-06-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI27531 UI27532

Modules/Macros

  • CQMOXGAX CQMOXGBX CQMOXG9X
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R310 PSY UI27531

       UP15/05/19 P F505

  • R320 PSY UI27532

       UP15/05/19 P F505

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
01 June 2015