A fix is available
APAR status
Closed as program error.
Error description
Users may be unable to start the CAE server after applying PH09505 (UI63353 & UI63354). ERROR: cannot open pathname\rt.jar for reading APAR PH09505 will need to be marked PE. . Possible workaround would be to uninstall CAE, install the GA version (base level) and then install latest PTF.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IBM Db2 Query Monitor for z/OS 3.3.0 * * users of component * * - CAE server * **************************************************************** * PROBLEM DESCRIPTION: Missing JRE during installation on * * Windows platform * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** During installation of CAE from APAR PH09505 on Windows platform old JRE is removed but new one is not installed.
Problem conclusion
Configuration of installer (InstallAnywhere) was fixed Search Keywords: CAE Windows JRE InstallAnywhere
Temporary fix
Comments
APAR Information
APAR number
PH14434
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
330
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-07-12
Closed date
2019-07-12
Last modified date
2019-08-01
APAR is sysrouted FROM one or more of the following:
PH14256
APAR is sysrouted TO one or more of the following:
UI64187
Modules/Macros
CQMBLOB CQMCCRT CQMJAR CQMPTFRM CQMSWD
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
R330 PSY UI64187
UP19/07/19 P F907
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.