Error description
Some date and time variables in templates may be resolved at job build time instead of run time. This fix will allow the variables to be used in the generated JCL rather than having them resolved at build time. This will only occur if the 'Gen Image Copy DSNs in GMT' flag is set to 'Y', otherwise the variables will be resolved at build time and the actual values, not the variables will be placed in the generated JCL. These variables will be affected: Time, Date, Year, Month, Day, Julian Day, Hours, Minutes, Seconds.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Automation Tool. * **************************************************************** * PROBLEM DESCRIPTION: Some date and time variables in * * templates may be resolved at job build * * time instead of run time. This fix will * * allow the variables to be used in the * * generated JCL rather than having them * * resolved at build time. This will * * only occur if the 'Gen Image Copy DSNs * * in GMT' flag is set to 'Y', otherwise * * the variables will be resolved at * * build time and the actual values, not * * the variables will be placed in the * * generated JCL. * * These variables will be affected: * * Time, Date, Year, Month, Day, * * Julian Day, Hours, Minutes, Seconds. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PK16315
Reported component name
DB2 AUTOMATION
Reported component ID
5697G6300
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2005-12-06
Closed date
2006-02-23
Last modified date
2006-03-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK12063
Modules/Macros
HAA$BDSN
Fix information
Fixed component name
DB2 AUTOMATION
Fixed component ID
5697G6300
Applicable component levels
R220 PSY UK12063
UP06/02/28 P F602