Troubleshooting
Problem
The message "is not defined" is seen after installing a function to Resilient Circuits.
2020-02-13 07:03:09,914 WARNING [actions_component] 'fn_virustotal.components.virustotal.FunctionComponent' function 'virustotal' is not defined!
2020-02-13 07:03:09,914 WARNING [actions_component] 'fn_exchange.components.exchange_get_mailbox_info.FunctionComponent' function 'exchange_get_mailbox_info' is not defined!
2020-02-13 07:03:09,915 WARNING [actions_component] 'fn_exchange.components.exchange_delete_emails.FunctionComponent' function 'exchange_delete_emails' is not defined!
2020-02-13 07:03:09,915 WARNING [actions_component] 'fn_exchange.components.exchange_find_emails.FunctionComponent' function 'exchange_find_emails' is not defined!
2020-02-13 07:03:09,916 WARNING [actions_component] 'fn_exchange.components.exchange_create_meeting.FunctionComponent' function 'exchange_create_meeting' is not defined!
2020-02-13 07:03:09,916 WARNING [actions_component] 'fn_exchange.components.exchange_move_folder_contents_and_delete_folder.FunctionComponent' function 'exchange_move_folder_contents_and_delete_folder' is not defined!
2020-02-13 07:03:09,916 WARNING [actions_component] 'fn_exchange.components.exchange_send_email.FunctionComponent' function 'exchange_send_email' is not defined!
2020-02-13 07:03:09,917 WARNING [actions_component] 'fn_exchange.components.exchange_move_emails.FunctionComponent' function 'exchange_move_emails' is not defined!
Cause
This message is caused because the new function has not been imported into Resilient.
Resolving The Problem
Import the function into Resilient via the command resilient-circuits customize.
See the documentation that accompanies the function to ensure that all steps are followed and the function is imported correctly.
Document Location
Worldwide
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSIP9Q","label":"IBM Security SOAR"},"Component":"Resilient Circuits","Platform":[{"code":"PF006","label":"CentOS"},{"code":"PF043","label":"Red Hat"},{"code":"PF033","label":"Windows"}],"Version":"All Versions","Edition":"","Line of Business":{"code":"LOB24","label":"Security Software"}}]