IBM Support

Transformation Extender Pack for Healthcare V10.0.3 Fix List

Release Notes


Abstract

This document provides a complete list of fixes for Transformation Extender Pack for Healthcare V10.0.3. The most recent fix is at the top of the table.

Content

Note: An APAR link does not work if the APAR has not reached the publish phase yet.

Entitled customers can download Transformation Extender Pack for Healthcare V10.0.3 from Fix Central.

APAR Description
PH23048 WHEN DATA ELEMENTS IN LIN OR CTP SEGMENT IN 2410 LOOP ARE NOT USED, COMPLIANCE CHECK NOT CONSISTENTLY REPORTING ERRORS IN 999
PH23047 ISSUES WITH HI OCCURRENCE SPAN CODE DATE ERRORS AND OCCURRENCE CODE DATE ERRORS
PH22274 HIPPA PACK 277CA QTY_01 COMPONENTS IN QTY SEGMENT PARTITIONS NEED IDENTIFIER ON
PH21520 COMPLIANCE ERROR FOR MONETARY AMOUNTS IN CAS06, 09, 12, 15, AND 18 THAT ARE TOO LONG ARE BEING INCORRECTLY REPORTED AS MISSING
PH21517 837I NOT FAILING COMPLIANCE WHEN THE DECIMAL POINT IS TRANSMITTED WITH THE DIAGNOSIS CODE.
PH21228 59163 - 59167 BUSINESS RULES ADDED FOR THE 837D WILL HAVE A PROBLEM WITH CONFIGURABLE RULES
PH21218 HIPAA COMPLIANCE CHECK - UNABLE TO PROCESS 60MB+ FILES
PH20462 837 2400 REF LINE ITEM CONTROL NUMBER PASSES COMPLIANCE CHECK WHEN THERE ARE MULTIPLE 2400 REF*6 WITHIN A CLM01
PH19686 COMPLIANCE CHECK 999 ERROR CODE INCORRECT FOR IMPLEMENTATION "NOT USED"
PH19685 837 2300 REF PAYER CLAIM CONTROL NUMBER IS REQUIRED WHEN CLM0503(CLAIM FREQUENCY CODE) INDICATES A REPLACEMENT OR VOID
PH19636 NEED DIFFERENT TERM IN TACK OUTPUT WHEN TACK REPORTS "SKIP" IF COMPLIANCE FAILS ONLY IN PRE-CONTENT CHECK OF TYPE 4 ERRORS
PH19497 CLAIM LEVEL REJECTION ACCEPTS INVALID DATA IF ERRORS OCCUR AT BOTH CLAIM LEVEL AND OUTSIDE OF THE CLAIMS
PH19489 ERROR CODES IN IK403 ELEMENT OF 999 (005010X231) 2110 IK4 SEGMENT DO NOT ALWAYS CORRESPOND WITH ACTUAL ERROR CONDITION
PH19354 837P & 837D TRANSACTIONS NOT FAILING WHEN LOOP 2320 SBR05 EXIST AND LOOP 2320 SBR01 = "P" AND SBR09 = MA, MB, OR 16
PH19353 EDIT 59113 - 2320 AMT="D" MUST BE PRESENT WHEN 2320 CAS PRESENT
PH18745 COMPLIANCE CHECK 837P WHEN PWK05 IS MISSING AND PWK06 IS PRESENT THE ERROR CONDITION IS REPORTED TWICE

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSQ9TT","label":"IBM Sterling Transformation Extender Pack for Healthcare"},"Component":"Pack for Healthcare","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"},{"code":"PF033","label":"Windows"},{"code":"PF035","label":"z\/OS"}],"Version":"10.0.3, 10.0.3.0","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]