5.3.7 Limitations and Known Issues for IBM Spectrum Control

Preventive Service Planning


Abstract

This document provides information about limitations and known issues that you might encounter when you use IBM® Spectrum Control™ 5.3.7

Content

This document contains the following sections:


Support links and Documentation

To access all of the support documentation, including alerts and APARs, go to the IBM Support Portal.

For information about the devices that are supported by IBM Spectrum Control, see the Supported Hardware, Products and Platforms Interoperability Matrix Links at http://www.ibm.com/support/pages/node/388393

IBM Spectrum Control Knowledge Center: http://www.ibm.com/support/knowledgecenter/SS5R93_5.3.7/

PDF guides for IBM Spectrum Control: http://www.ibm.com/support/knowledgecenter/SS5R93_5.3.7/com.ibm.spectrum.sc.doc/fqz0_r_printable_pdf_files.html

For a list of the known issues with the IBM Spectrum Control support for Hitachi Data Systems Virtual Storage Platform, see http://www.ibm.com/support/pages/node/241805

____________________

Product licenses for IBM Spectrum Control

IBM Spectrum Control 5.3.7 offers product licenses with differing functionality to meet your storage management needs. For information about these licenses, see http://www.ibm.com/support/knowledgecenter/SS5R93_5.3.7/com.ibm.spectrum.sc.doc/fqz0_r_product_packages.html

 


Installation, Upgrade, and Configuration

____________________

Adding storage systems failure occurs after a successful new installation of IBM Spectrum Control 5.3.7 with custom ports


After you perform a successful new installation of IBM Spectrum Control 5.3.7 with custom ports, you cannot add storage systems to your environment. You must complete a re-installation of IBM Spectrum Control 5.3.7 using the default ports in order to successfully add storage systems.

____________________

The Server Keystore Password panel might appear unexpectedly when you upgrade to IBM Spectrum Control 5.3.7 on Windows


If you upgrade to IBM Spectrum Control 5.3.7 on Windows and you unexpectedly see the Server Keystore Passwords panel, do the following steps:

1.  Cancel out of your upgrade to IBM Spectrum Control 5.3.7.
2.  Rename the sub-directory  <installation_dir>\jre.bck   to   <installation_dir>\jre
3.  Restart your Windows machine.
4.  Perform your upgrade to IBM Spectrum Control 5.3.7.

___________________

The IBM Spectrum Control 5.3.7 installation might appear to hang at Database component upgrade while database tables are cleaned up and migrated 
When upgrading IBM Spectrum Control 5.2.11 or earlier to 5.2.16 or later, you might experience a long duration of the upgrade where it appears to hang while database tables are cleaned up and migrated.  This is a known limitation, and is a required migration step that (depending on your database size) might take a long time to complete.  It is a one-time only clean up process, and will not occur during the next upgrade of IBM Spectrum Control.

You can review the log files to determine if your upgrade is undergoing this database clean and migration process:  In traceTPCInstall.log look near the end of the log file, there would be an executing SQL statement similar to one of these:
"SET INTEGRITY FOR T_RPT_HOST_KEYS ..."  or  "REFRESH TABLE T_RPT_HOST_KEYS ..."
And the last lines in the log file during the process would be similar to this:
"... INFO com.ibm.tpc.install.frontend.ia.actions.ProgressBarUpdater setPercentageComplete Seconds complete = ..."

 

General IBM Spectrum Control issues

____________________

APAR IT31680: Showing zero value for some IBM SAN Volume Controller and IBM Storwize storage capacities

IBM Spectrum Control and IBM Storage Insights are showing zero values for some storage capacities values such as Physical Capacity and Allocated Capacity for monitored SAN Volume Controller or Storwize storage systems that run firmware level below 8.2.

This issue happens due to an SAN Volume Controller CLI 8.1.x limitation surfacing which is visible in IBM Spectrum Control and IBM Storage Insights after upgrading to 5.3.5 or higher, where the capacity values for SAN Volume Controller family devices had changed to rely on the SAN Volume Controller physical capacity values.

The issue only affects SAN Volume Controller family devices, and does not impact FlashSystem 900 devices.

The issue is resolved in the newer versions of SAN Volume Controller firmware, starting with:

  • 8.1.3.6
  • 8.2.1.4

For details see SAN Volume Controller APAR HU01916: The GUI Dashboard and the CLI lssystem command report physical capacity incorrectly
https://public.dhe.ibm.com/storage/san/sanvc/release_notes/813_releasenotes.html#APARs

____________________

APAR IT24763: Adding or modifying the connection information for an IBM FlashSystem V9000

When adding or modifying the connection information, be sure to use the correct credentials for the FlashSystem V9000: the connection information for the V9000 control nodes.

Probe of a FlashSystem V9000 will fail if connection credentials were for the internal FlashSystem 900 module rather than providing connection information for the V9000 control nodes.

The reported IBM Spectrum Control probe error is:  CMMVC7205E The command failed because it is not supported

IBM Spectrum Control can only manage the control nodes of a V9000 cluster, it cannot manage the backend Flashsystem module.

____________________

APAR IT23975: Port down/offline alerts generated for FlashSystem 900 when the port is simply unused/disconnected.

IBM Spectrum Control is generating "error" alerts for an IBM FlashSystem 900 storage device for ports that are not physically connected to a SAN.  IBM Spectrum Control is receiving port alerts for ports that are known to be disconnected, and no matter the suppression settings selected, the alerts continue to be generated. 

This differs from the way that all other IBM storage operates, including SAN Volume Controller, Storwize, and other IBM storage where unused ports do not trigger alerts and do not report errors about unused ports.  Typically, port alerts should only trigger if a port that was connected then becomes disconnected.  That is how the rest of IBM storage environment operates.  At this time, there is no way to make this behavior consistent with other IBM storage.

The alert for an inactive and configured FlashSystem port is working as designed because the condition is an "offline" status, which aligns with the FlashSystem GUI.  Inactive and unconfigured FlashSystem ports do not represent an error condition to generate alerts in IBM Spectrum Control.  The different port status inactive configured / inactive unconfigured reported by FlashSystem device are due to the installed small form-factor pluggable (SFP) transceivers onto the interface card in the system canister.  When SFP is installed and the port is not connected, the status reported by FlashSystem is inactive and configured port.

The workaround for changing the port status is to remove the unused SFP and reset the interface card in the canister.  More information how to add/remove SFPs to the FlashSystem storage enclosure can be found in the FlashSystem knowledge center at https://www.ibm.com/support/knowledgecenter/STKMQB_1.6.1/com.ibm.storage.flashsystem900.1.6.1.doc/tms_add_sfps.html.

____________________

Incorrect overhead capacity value for block storage systems

IBM Spectrum Control might report an incorrect overhead capacity for some block storage systems such as XIV, EMC Unity, FlashSystem 9100 and FlashSystem A9000. 

____________________

Provisioning fails when requesting compressed volumes from a data reduction pool

When you provision compressed volumes from storage systems that run IBM Spectrum Virtualize 8.1.1 or later, you might see the following error message:

HWNCA0005E  IBM Spectrum Control cannot provide the requested <n> GiB of capacity that also satisfies the requirements of the service class.

This issue occurs under the following conditions:
- The service class specifies that the storage resources must be able to compress volumes.
- IBM Spectrum Control attempts to provision the storage from a data reduction pool.

To work around this issue, use a service class that does not specify that the storage resources must be able to compress volumes. Alternatively, ensure that the available IBM Storage Virtualizers contain storage pools that are not configured as data reduction pools.

____________________

HDS back-end storage devices behind a SAN Volume  shows as "not monitored"

IBM support worked with Hitachi support and this is the answer from Hitachi:  We have identified the root cause and are working on new SVP SMI-S Provider code to fix the issue.

Details: When IBM SMI-S Spectrum Control version 5.2.15.0 sends query “HITACHI_StorageProcessorSystem”, the Controller ID on DKC1 side that the SVP SMI-S provider calculates was incorrect; so IBM SMI-S Spectrum Control version 5.2.15.0 does not receive the port information for DKC1 side correctly from the SVP.
 
Unfortunately there is no workaround at present. The permanent fix will be to upgrade to the new code. You can see the status of this APAR here: http://www.ibm.com/support/docview.wss?uid=swg1IT25032

____________________

Submitting two tiering tasks to run at the same time or overlap might cause one of them to not complete 

When submitting two tiering tasks to run at the same time or overlap their running times, they might stall and fail to complete.  There are no errors displayed, and the logs indicate that the tasks are still running, however if they stall no further tasks are updated or completed.  This situation can occur for the first tiering task or for both.

To avoid this problem, submit one tiering task at a time and wait for it to complete before submitting another tiering task.

____________________

In Metro Mirror or Global Copy relationship, if a Peer to Peer Remote Copy (PPRC) is terminated and then deleted on one of the storage systems, the other storage system retains the relationship  
If a storage system is not aware of the termination due to the loss of the PPRC path, volumes on that system might be counted as both unprotected and protected.

To correct the reporting, take one of the following actions:

  • Issue a terminate to the storage system, which retains the relationships.
  • Reestablish the PPRC paths and the relationship by using the dscli command or another copy services management tool (such as the CSM product).

____________________

Provisioning fails with ADD_PORTS_TO_HOST message on XIV 11.5.0 when modifying host   

When trying to provision storage from an IBM XIV® 11.5.0 system, the provisioning task fails with an "ADD_PORTS_TO_HOST task failed" message when trying to provision storage to a host that is already defined on the XIV subsystem.  This can happen when the host definition does not contain all the Fibre Channel ports that IBM Spectrum Control is trying to assign the volume to.

For example, if you try to provision storage to a host that has 2 Fibre Channel ports and the host is
already defined on the XIV 11.5.0 system but with only one of the Fibre Channel ports, the assign job will fail and the second port will not be added to the host.

This condition does not occur when IBM Spectrum Control is creating the host definition, or when an existing host definition already has all ports defined. This issue does not occur with XIV 11.4 systems, and 11.5.1 or later systems.

Workaround: modify the host definition on the XIV 11.5.0 system to contain all the Fibre Channel ports, then run a probe of the XIV 11.5.0 system in IBM Spectrum Control or upgrade to XIV 11.5.1 or later.

____________________

Enabled ethernet port that is not connected to a switch can cause the GUI to hang  

On some IBM servers running Windows 2012, an enabled ethernet port can cause the IBM Spectrum Control GUI to stop responding if the port is not connected to a switch.  This condition causes a Db2 SQL -911 error and also causes the IBM Spectrum Control GUI to stop responding.

To prevent this, disable the ethernet port or configure the port by using the instructions at  https://publib.boulder.ibm.com/infocenter/bladectr/documentation/index.jsp?topic=/com.ibm.bladecenter.hs22.doc/dw1iu_t_lan_over_usb_install_windows_driver_install.html

____________________

Disable Windows User Account Control to edit configuration files

On Windows installations, if you installed IBM Spectrum Control by using a domain user account, you must disable User Account Control to edit the IBM Spectrum Control configuration files.

____________________

IBM Spectrum Control cannot detect the mount status of file systems on Storwize V7000 Unified storage systems   

If a file system is manually unmounted from a Storwize® V7000 Unified storage system, IBM Spectrum Control cannot detect that the file system was unmounted. Because of this limitation, information that is displayed in the IBM Spectrum Control GUIs is not accurate and some storage-related actions on the file system might fail.

For example, when you provision storage, a file system on a Storwize V7000 Unified storage system might be recommended for provisioning. However, if that file system was manually unmounted after it was first detected by IBM Spectrum Control, the provisioning action will fail. An unmounted file system cannot be used for provisioning. To avoid this issue, ensure that the monitored file systems on the Storwize V7000 Unified storage system are mounted before you run the provisioning action.

____________________

 

IBM SAN Volume Controller and IBM Storwize devices might not accurately report used space of data reduction pools and deduplicated volumes

When an SAN Volume Controller or Storwize device is configured with data reduction pools, it (on certain firmware levels, including 8.1.3.3) no longer reports the used space for a specific volume, and the tier distribution is no longer reported.  This is a limitation from the firmware with data reduction pools/deduplicated volumes.

____________________

Running multiple optimization recommendations at the same time results in a Pool Exhaustion Exception error  

In some cases, running more than 15 optimization recommendations at the same time can cause one or more of the individual recommendation executions to result in a Pool Exhaustion Exception error. This can be caused by a lack of available resources in the operating system thread pool. You can manually complete the failed recommendations.

____________________

Setting the rate at which data is copied between volumes that run IBM Spectrum Virtualize

IBM Spectrum Control can do tasks that significantly alter the structure of storage. For example, IBM Spectrum Control can add a mirrored volume copy, or migrate volumes from one pool to another by using storage optimization functions. When IBM Spectrum Control performs these tasks, a default synchronization rate of 100% is set.

For more information about how to change the synchronization rate, see the "Changing the synchronization rate for volumes on SAN Volume Controller or Storwize family systems"  http://www.ibm.com/support/knowledgecenter/SS5R93_5.3.7/com.ibm.spectrum.sc.doc/tbs_svc_setting_sync_rate.html.

____________________

Probes with a Storage Resource agent (SRA) on Linux servers hang and remain "In Progress" forever

SRA probes run Logical Volume Manager (LVM) commands and these can hang which causes the SRA to hang and appear to be "In Progress" indefinitely.  

To verify that this is the situation causing the hang, view the SRA agent trace log on the SRA Deployment and verify that the last command was an LVM one.

To recover from this situation:

  1. Kill the hung SRA process
  2. Kill the hung LVM command
  3. From a command line, retry the LVM command and verify that it runs successfully. If it does not, use the LVM documentation to repair the LVM so that it does.  
  4. Restart the SRA

You can follow the progress of the APAR related to this issue here:  http://www.ibm.com/support/docview.wss?uid=swg1IT15105

____________________

RHEL known issues with fprintd-pam module (fingerprint authentication module)

The fprintd-pam module (fingerprint authentication module) has some known issues in various environments.  Review the details on redhat.com:
In some instances the fprintd-pam module can cause the IBM Spectrum Control web server to crash.  If you don't need the fingerprint authentication service, it's recommended that you uninstall the fprintd packages to avoid any potential problems. 


____________________

Application Groups and Aggregated Metrics 

For application groups, the performance data is aggregated from the volumes added to the group, either directly or using a filter.  The values displayed for the aggregated Read Response Time, Write Response Time, and Overall Response Time are incorrect.  All other metrics currently supported for application aggregation are rendered correctly.

____________________

IBM Spectrum Control might report incorrect vmdk size and incorrect capacity of VM

IBM Spectrum Control persists the relation between a vmdk and vmdisk, restricting the relation to vmdisk <-> current vmdk file. The current vmdk file has an aggregate size which includes the sizes of snapshots up to the current vmdk file. IBM Spectrum Control associates the latest running delta file with vmdisk, hence IBM Spectrum Control might report the size smaller than actual size of the vmdisk if there are newer snapshots (which are not included in the current vmdk size).

____________________

Export Performance Data Tool  

The output format from the exportPerformanceData Script has changed in IBM Spectrum Control 5.3.7. To minimize the impact of this and all future output format changes,  users of the CSV files are encouraged to parse the column headers they are interested in.

____________________

Spectrum Scale cluster with configured sudo-wrapper environment can not be managed with Spectrum Control or Storage Insights

This configuration is not supported since mmdsh commands are needed to collect various configuration information from the Scale Cluster.  


Non-IBM Storage Support Issues

Non-IBM storage devices will only show node relationships in the Volumes table if the relationship is 1:1.  Therefore if a volume resides on more than 1 node, the node column will be empty for that volume.
 


EMC Support Issues

In 5.3.0 and later, you can view more information about the capacity, space usage, and performance of EMC™ storage systems. However, keep in mind the following issues for EMC support:

On the details page for an EMC storage system, duplicate NAS nodes might be displayed if the EMC's NAS Servers support both NFS and CIFS protocols. This issue occurs because each protocol represents a node. For example, on the same NAS server, if NAS1451 supports NFS and NAS1451 supports CIFS protocols, two node entries are displayed on the details page for the storage system.

Information about both FC and Serial Attached SCSI (SAS) ports are returned when FC ports are probed.

VNXe:
Thin-provisioned volumes: The value for allocated space is incorrect.
Total or available capacity values of each storage tier in a storage pool are incorrect.

VNX:
Thin pools: The value for physical allocated space is incorrect.
File system pools are not displayed.
Total or available capacity values of each storage tier in a storage pool are incorrect.
The VNX regular thin pool's "pool capacity" value, returned by EMC SMI-S provider, is slightly lower than reported by the element manager.  This applies only to VNX thin pool, referred to as "Pools" in Unisphere.
Disk and volume response times and utilization percentages: The displayed values for these metrics are higher than their actual value.
 
VMAX3:
Available pool space or any allocated capacity values are always 0.
All aggregated volume capacity values are 0 because of the missing relationship between pools and volumes.
Mappings of volume to pool and volume to disk are not displayed.

Reporting: In Cognos Analytics, pre-defined reports might not be available for EMC storage systems.

Unity:
In 5.3.5 and later, you can monitor Unity devices. Due to the mismatch of old FS UID format from 5.3.5 probe and new FS UID format from 5.3.6 and later PM data collection, no file system metrics will be displayed until a manual or next schedule probe  / data collection is run on Unity.

Isilon:
Dell EMC Isilon devices are not yet supported for monitoring in IBM Spectrum Control.


 


NetApp Support Issues

For NetApp systems Copy Data can not correlate data, so no links are shown.


 


HDS Support Issues

Hitachi VSP systems are supported as virtualizers and show the backend storage system and external disks.  It is not possible to show managed disks mapped directly to a host.


 


Pure Support Issues

If IBM Spectrum Control is monitoring a Pure system that is in asynchronous relationship with another storage system, details of the target system are not available.  IBM Spectrum Control will list the target system however the remote volumes can not be correlated hence a link will not be displayed in the user interface. 

If IBM Spectrum Control is monitoring only the target system of asynchronous relationships, no details of the source system are available.


 


Cognos Analytics

____________________

Cognos Analytics 11.1.4, bundled with Spectrum Control, does not support Db2 11.5 

If you plan to use IBM® Cognos® Business Intelligence reports in IBM Spectrum Control, you can install IBM® Cognos® Analytics 11.0.9 or later (up to and including 11.1.4) and migrate your reports. 

Currently, Cognos Analytics does not support Db2 11.5, so if you plan on using Cognos Analytics we strongly suggest using Db2 11.1.x for Spectrum Control to avoid problems with Cognos Analytics report integration.  To continue to use Cognos Analytics, use Db2 11.1 parts listed here:  https://www.ibm.com/support/pages/node/6205756.  Review supported platforms matrix to ensure all products you plan to install on the machine support the same level of Db2: https://www.ibm.com/support/pages/ibm-spectrum-control-53x-servers-agents-and-browsers.

____________________

GPFS/GSS/Spectrum Scale is not supported in Cognos Analytics

GPFS/GSS/Spectrum Scale™ file systems are not correctly represented in Cognos reports and are not supported in Cognos.

Information is not collected about NFS and CIFS exports that are defined on a GPFS/GSS/Spectrum Scale clusters.

____________________

Links to Help in IBM Spectrum Control 5.3.7 predefined reports open the public IBM Spectrum Control Knowledge Center

When using the Cognos Analytics User Interface to generate IBM Spectrum Control predefined reports, the Help link will open the IBM Spectrum Control Knowledge Center on ibm.com.  The system running Cognos Analytics will need access to the internet to open to the knowledge center.  

 


Documentation Updates and Corrections

Check here for missing, updated, or corrected information in the documentation for IBM Spectrum Control.

Dell EMC Isilon is not supported

The online help that you can access from the Help menu in IBM Spectrum Control incorrectly states that Dell EMC Isilon is supported. That information is incorrect. You can't currently use IBM Spectrum Control to monitor Dell EMC Isilon devices.

In the online help, the page with this incorrect information is located here in the navigation: Configuring > Adding resources > Dell EMC > Planning for Dell EMC storage systems. 


 


Browser Issues

____________________

Browser displays a security certificate error 

Some browsers will display: "There is a problem with this website's security certificate."  when you log in to IBM Spectrum Control. To continue to the GUI, click "Continue to this website" and you will be returned to the previous page.  This behavior does not occur on all browsers.


 

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS5R93","label":"IBM Spectrum Control"},"Component":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.7","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS5R93","label":"IBM Spectrum Control"},"Component":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.7","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS5R93","label":"IBM Spectrum Control"},"Component":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.7","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWFCQ","label":"IBM Spectrum Control Standard Select Edition"},"Component":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.7","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
23 March 2022