Fixes are available
APAR status
Closed as program error.
Error description
Tested in RIT 9.0 In order to test I did this: 1. Create an HTTPS transport for www.gooGLe.co.uk 2. Switch on SSL and test connection works with the default "trust all" 3. Now export the certificate from that site from your browser and save it. 4. Create a new Identity Store and import this cert. 5. Change the transport and set "Server certificates to trust" to be your Identity Store. 6. Now test connections fails with: [CRRIT1707E] Could not create a connection to the HTTP server : java.security.cert.CertificateException: The names on the security certificate: "[www.google.co.uk]" do not match the name of the site "WWW.gooGle.CO.uk" JC confirms that this is a defect and can see why in the code.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of Rational Integration Tester working with host * * names for physical transports * **************************************************************** * PROBLEM DESCRIPTION: * * Host names for physical transports are case-sensitive, * * causing TLS negotiations to fail. * **************************************************************** * RECOMMENDATION: * * Upgrade to Rational Integration Tester v9.0.1 which includes * * a fix for this issue * ****************************************************************
Problem conclusion
A fix for this issue was provided in version 9.0.1 of Rational Integration Tester.
Temporary fix
Comments
APAR Information
APAR number
PI64351
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
870
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-06-16
Closed date
2016-09-20
Last modified date
2016-09-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSN
UP
R900 PSN
UP
R901 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.7","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
17 October 2021