A fix is available
APAR status
Closed as program error.
Error description
In earlier versions of COBOL, customer source frequently handled dynamically sized pieces of storage by using a PIC X(1) linkage section data-item and then reading or writing beyond the bounds of that array. This APAR will add this type of support to COBOL V5 to make the behavior consistent with COBOL V4. LINKAGE Example: WORKING-STORAGE SECTION. 01 wrk-len PIC s9(08) binary. LINKAGE SECTION. 01 L-String1 PIC X(1). 01 L-String2 PIC X(1). PROCEDURE DIVISION. 0000-MAIN. MOVE 1000 TO wrk-len MOVE L-String1(1:wrk-len) TO L-String2(1:wrk-len) Behavior difference: COBOL V4 moves 1000 bytes. COBOL V5 moves 232 bytes due to differing instructions. TABLE ODO Example: WORKING-STORAGE SECTION. 01 CONTROLVAR PIC 9(5) BINARY. 01 MYCONTAINER. 02 MYTABLE. 03 TBL OCCURS 0 TO 1 TIMES DEPENDING ON CONTROLVAR. 05 MYFIELD PIC X(1). 02 DUMMY PIC X(300). PROCEDURE DIVISION. MOVE 1 TO CONTROLVAR MOVE ALL 'Z' TO DUMMY DISPLAY DUMMY <= Contains all Z's MOVE 300 TO CONTROLVAR MOVE ALL 'M' TO MYTABLE <= MYTABLE has 1 byte of M's in V4 DISPLAY MYTABLE MOVE 1 TO CONTROLVAR DISPLAY DUMMY <= DUMMY HAS 299 BYTES OF M's in V4. Behavior difference: COBOL V4 overlays storage following MYTABLE exactly as expected byte for byte. COBOL V5 handles the overlay differently such that the storage results differ from COBOL V4.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 5.2 compiling and * * running programs that are compiled with the * * OPT(1) or OPT(2) compiler options and are * * using a variable length reference * * modification to deliberately move data into * * a linkage section data item beyond its * * defined length. * * * **************************************************************** * PROBLEM DESCRIPTION: Incorrect output. The number of bytes * * that are moved into the receiver is * * capped at the defined length of the * * receiver data item, which may be * * shorter than the runtime length of the * * reference modification in the move * * operation. This behavior differs from * * pre-V5 releases of the Enterprise * * COBOLcompiler, which did not attempt * * to cap the length of such move * * operations. * * * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** Consider two COBOL programs, PROGA and PROGB: PROGA: DATA DIVISION. WORKING-STORAGE SECTION. 01 DATA1 PIC X(100). PROCEDURE DIVISION. CALL PROGB USING BY REFERENCE DATA1 PROGB: DATA DIVISION. WORKING-STORAGE SECTION. 01 LEN PIC 9(5) BINARY. LINKAGE SECTION. 01 DATA1 PIC X(1). 01 DATA2 PIC X(500). PROCEDURE DIVISION USING BY REFERENCE DATA1. : MOVE 100 to LEN MOVE DATA2(1:LEN) TO DATA1(1:LEN) When optimizing PROGB, the compiler was capping the length of the move in statement 'MOVE DATA2(1:LEN) TO DATA1(1:LEN)' to 1 byte, which technically is the maximum length of the move based on the definition of DATA1 in PROGB, but this behavior is different from pre-V5 releases of the compiler which allowed users to simulate unbounded parameters using this pattern.
Problem conclusion
The compiler was updated to ensure that in the above move scenario the runtime length of the move, as implied by the variable length reference modification, is always used regardless of the defined length of the receiving data item in the linkage section.
Temporary fix
Comments
APAR Information
APAR number
PI59330
Reported component name
ENT COBOL FOR Z
Reported component ID
5655W3200
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-17
Closed date
2016-03-23
Last modified date
2016-04-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGYCCBE
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655W3200
Applicable component levels
R520 PSY UI36448
UP16/03/30 P F603
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"","label":""}}]