Fixes are available
Rational Developer for System z Fix Pack 1 (9.5.1.1) for 9.5.1.
Rational Developer for z Systems Interim Fix 1 for 9.5.1.1
Rational Developer for z Systems Interim Fix 2 for 9.5.1.1
Rational Developer for z Systems Interim Fix 4 for 9.5.1.1
Rational Developer for System z Fix Pack 2 (9.5.1.1) for 9.5.1.
Rational Developer for System z Fix Pack 3 (9.5.1.1) for 9.5.1.
Rational Developer for System z Fix Pack 4 (9.5.1.4) for 9.5.1.
Rational Developer for System z Fix Pack 5 (9.5.1.5) for 9.5.1.
Rational Developer for System z Fix Pack 5 (9.5.1.6) for 9.5.1.
Rational Developer for z Systems Fix Pack 7 (9.5.1.7) for 9.5.1.
Rational Developer for z Systems Fix Pack 8 (9.5.1.8) for 9.5.1.
Rational Developer for z Systems Fix Pack 9 (9.5.1.9) for 9.5.1.
Rational Developer for z Systems Fix Pack 10 (9.5.1.10) for 9.5.1.
Rational Developer for z Systems Fix Pack 11 (9.5.1.11) for 9.5.1.
Rational Developer for z Systems Fix Pack 12 (9.5.1.12) for 9.5.1.
APAR status
Closed as program error.
Error description
In Rational Developer for System z - RDz - v9.5.0, attempts to create a testcase with zUnit for a VSAM dataset (ESDS,KSDS, RRDS) fails with errors like: In case of KSDS dataset (ORGANIZATION IS INDEXED) 04.59.53 JOB00739 IEC130I MYKSDS DD STATEMENT MISSING In case of ESDS dataset (ORGANIZATION IS SEQUENTIAL) 19 IGYGR0096-S A "RECORDING MODE" clause was found for a file that did not have physical "SEQUENTIAL" organization. The "RECORDING MODE" clause was discarded. RDz zUnit does not support VSAM datasets.
Local fix
There is no known workaround at this time.
Problem summary
Attempts to create a testcase with zUnit for a VSAM dataset (ESDS,KSDS, RRDS) fails with errors like: In case of KSDS dataset (ORGANIZATION IS INDEXED) 04.59.53 JOB00739 IEC130I MYKSDS DD STATEMENT MISSING In case of ESDS dataset (ORGANIZATION IS SEQUENTIAL) 19 IGYGR0096-S A "RECORDING MODE" clause was found for a file that did not have physical "SEQUENTIAL" organization. The "RECORDING MODE" clause was discarded. RDz zUnit does not support VSAM datasets.
Problem conclusion
zUnit has been corrected so that warning dialog is displayed in generating a test case when the test target source contains VSAM definition. The problem listed in this APAR has been resolved with IBM Rational Developer for System z V9.5.1.1 Fix Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PI58362
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-02
Closed date
2016-05-27
Last modified date
2016-05-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R951 PSY
UP
Document Information
Modified date:
15 October 2021