IBM Support

PI54415: Requests with CONTENT-LENGTH: 0 and any LimitRequestBody may result in a 413 error

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The scope of the check of total_read is such that it was never
    read since it was not explicitly initialized.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  Users of IBM HTTP Server                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Unexpected 413 HTTP response code for   *
    *                      requests with Content-Length: 0 and     *
    *                      any LimitRequestBody.                   *
    ****************************************************************
    * RECOMMENDATION:  Apply this fix.                             *
    ****************************************************************
    When the body is zero-length, the variable representing the
    amount of data already read is not explicitly initialized (and
    it's never written to because nothing is read when zero bytes
    remain).
    

Problem conclusion

  • Explicit initialization has been added to resolve the problem.
    
    This fix is targeted for IBM HTTP Server fix packs:
    - 7.0.0.41
    - 8.0.0.13
    - 8.5.5.10
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI54415

  • Reported component name

    IBM HTTP SERVER

  • Reported component ID

    5724J0801

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-12-17

  • Closed date

    2016-01-29

  • Last modified date

    2016-01-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    IBM HTTP SERVER

  • Fixed component ID

    5724J0801

Applicable component levels

  • R700 PSY

       UP

  • R800 PSY

       UP

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTJ","label":"IBM HTTP Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: