Question

Are Guardium S-TAPs compatible with an earlier version? For example, will a v10 S-TAP work with a v11.x collector?

Answer

The Guardium S-TAP is compatible with an earlier version by one version, so v10 S-TAPs are compatible with v11 Collectors.

However:
- if your Collector is v11 - then the v11 S-TAP is generally the best option.
- if your Collector is v10 - then the v10 S-TAP is generally the best option.

While the Collector/ STAP versions can be mixed, the older version may not handle any new features - hence it is best to keep the Collector / S-TAP versions as close and up to date as possible.

If you have a question on compatibility for the following :-
Newer STAP -> Older Collector (eg v11 STAP -> v10 Collector) :-
- please log an IBM Support case and provide full details of the versions of the STAP, DB Server and Collector to the support engineer.
The Support team will then make checks as to the suitability of the proposed configuration.
List of tested newer STAP -> Older Collector verified as working
STAP v11.1.0.11_r109779 -> Collector v10.0p4050 (NOTE- any Sniffer below p4050 has issues)
Note for IBM Support engineers
Please refer to the "Internal Use Only"of this document for instructions on how to proceed with any query for Newer STAP-> Older Collector.

[{"Line of Business":{"code":"LOB24","label":"Security Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSMPHH","label":"IBM Security Guardium"},"ARM Category":[{"code":"","label":""}],"Platform":[{"code":"","label":"Platform Independent"}],"Version":"All Version(s)"}]