Setting up SLC's to run in IBM Control Center but not getting any messages from the SLC positive or negative.
Symptom
SLC's are not running
Cause
SERIAL_NUM is out of sync between the database tables
Diagnosing The Problem
First get the value of CC_CONTROLLER.LAST_EVENT_SERIAL_NUM_PROC
Then get the value of the largest and smallest EVENTS.SERIAL_NUM in the same database via the queries below:
- SELECT SERIAL_NUM FROM EVENTS ORDER BY SERIAL_NUM DESC
- SELECT SERIAL_NUM FROM EVENTS ORDER BY SERIAL_NUM ASC
Resolving The Problem
The value of CC_CONTROLLER.LAST_EVENT_SERIAL_NUM_PROC to be one less than the minimum EVENTS.SERIAL_NUM value.
Apply fix from APAR IT17057
[{"Product":{"code":"SS9GLA","label":"IBM Control Center"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Not Applicable","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"6.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]