Troubleshooting
Problem
Parallel synchronization might fail for version control-enabled HP ALM projects if IBM Rational DOORS is the Master EndPoint for Requirement and Test synchronization tasks.
Symptom
After parallel synchronization is completed, most of Requirement and Test entities remain checked-out.
The synchronization summary shows object errors for these objects and mapped attributes value are not updated in HP ALM.
Cause
The HP ALM REST API is not able to differentiate between Requirement and Test Entities while checking out objects in this scenario.
This issue was identified as a product defect and logged internally by IBM as defect 9693.
This issue is identified as defect by HP and it can be tracked as QCCR1J77320.
Environment
Operating system: Windows Server 2008
Rational DOORS version 9.6 32-bit client
Rational DOORS HP Quality Center Interface, version 3.6
HP ALM version 11.5
Resolving The Problem
You do not encounter this problem if none of the Requirement or Test Synchronization Tasks are executed in parallel for version control HP ALM projects.
Was this topic helpful?
Document Information
Modified date:
16 June 2018
UID
swg21693847