Question
How to define a rule that will handle the eventuality that a monitored C:D node is down at the time the Sterling Control Center engine is started?
Cause
If a C:D node goes offline during operation then it can be handled by setting a rule that looks for CCTR034E (monitored server down) and linked rule CCTR033E (monitored server up). These messages only occur when a node goes down or up in normal operation. When the engine is started and a monitored node is already down, different messages apply; CNCD071E and CCTR074E.
Answer
Add rules similar to the 2 below. Together, these two rules will detect server down/up both during and after engine startup.
===================================================================
Rule 1: CD OFFLINE
Rule Parameters: Message Id | Matches | CCTR034E
Linked Rule Parameters: Message Id | Matches | CCTR033E
===================================================================
Additional Rule 2: CD OFFLINE AT ENGINE STARTUP
Rule Parameters: Message Id | Matches | CNCD071E
Linked Rule Parameters: Message Id | Matches | CCTR074E
===================================================================