IBM Support

You cannot create an OSLC link from the Rational DOORS client to a Rational Team Concert 5.0 work item

Troubleshooting


Problem

Attempts to create an OSLC link from an object in the IBM Rational DOORS client (version 9.6 and earlier) to a work item in IBM Rational Team Concert version 5.0 results in the link not being completed because some required fields are not visible in the user interface.

Symptom

The following message is displayed after you enter values in the visible fields and click OK:

'Save Work Item' failed. Preconditions have not been met: The 'Filed Against' attribute needs to be set (work item <.....>).

The Filed Against field is not visible, so you cannot create the link.



Steps to reproduce:
  1. Log in to the Rational DOORS desktop client.

  2. Add a Rational Team Concert server as a friend and add an associated project.

  3. Open a requirements module, select an object, and try to create an OSLC link to Rational Team Concert.

    Result: The delegated user interface from Rational Team Concert only displays the Type, Summary, and Description fields.

  4. Enter values for the shown fields and click OK.

    Result: A message is displayed that indicates that the Filed Against field is missing a value. However, you cannot enter a value because the field is not shown. You are unable to create the OSLC link.

Cause

The Rational DOORS client version 9.6 and recent earlier versions includes embedded emulation for Internet Explorer 7. Rational Team Concert version 5.0 has upgraded support to Internet Explorer 11.

This issue was identified as a product defect and logged internally as defect 8353.

Environment

Rational DOORS 9.6

Rational Team Concert 5.0

System browser: Microsoft Internet Explorer 10 or 11

Resolving The Problem

This problem has been resolved as of Rational DOORS and Rational DOORS Web Access 9.6.1.

WORKAROUND:

To avoid this problem, create the OSLC link from the Rational Team Concert client or from the Rational DOORS Web Access client.

[{"Product":{"code":"SSKR2T","label":"IBM Engineering Requirements Management DOORS"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Integrations: IBM","Platform":[{"code":"PF033","label":"Windows"}],"Version":"9.6;9.6.0.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]