Question & Answer
Question
How do you relay an event generated by MULTICAS_GEN macro to more than one port located inside an composite class?
Cause
This is a known limitation.
Multicasting through regular ports are supported only in direct 1 hop.
In case of the image at right, multicasted events originated from portA can only be received by 1 port (either portC or portD).
Answer
WORKAROUND:
You can implement a delegator class that forwards any incoming events to inner ports. See the image below.
For details, refer the attached model built using v8.1. In this model, please notice below points.
- Property '<Lang>::Port::SupportMulticast' of 'portE2' is set to 'Always'.
- In statechart of delegator class (itsE), MULTICAST_GEN (for C++) and RiC_MULTICAST_GEN_PORT (for C) macro is used to multicast events, instead of having them called from itsA.
All source code and/or binaries attached to this document are referred to here as "the Program". IBM is not providing program services of any kind for the Program. IBM is providing the Program on an "AS IS" basis without warranty of any kind. IBM WILL NOT BE LIABLE FOR ANY ACTUAL, DIRECT, SPECIAL, INCIDENTAL, OR INDIRECT DAMAGES OR FOR ANY ECONOMIC CONSEQUENTIAL DAMAGES (INCLUDING LOST PROFITS OR SAVINGS), EVEN IF IBM, OR ITS RESELLER, HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. |
---|
Product Synonym
Rational Rhapsody
Was this topic helpful?
Document Information
Modified date:
27 May 2022