Error description
Personal Communications 5.9.2 on WindowsXP SP3 When trying to Start a PCOMM session , customer is getting a msg PCSERR100- "Error allocating 66050 bytes of memory from the Windows global memory heap Close one or more Windows applications and try again."
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users * **************************************************************** * PROBLEM DESCRIPTION: Intermittent PCSERR100 popup message * * when starting PCOMM sessions * **************************************************************** * RECOMMENDATION: * **************************************************************** While working with PCOMM sessions users intermittently gets PCSERR100 popup message and have to restart the machine to again work with PCOMM.
Problem conclusion
When PCSWLIB.DLL allocates memory it calls MapViewofFileEx on a block of virtual addresses. This entire block is supposed to be free at the point of allocation. The existing code had no check to verify the availability of this memory block. The code changes introduces this check by asserting ownership on the block about to be allocated. Fixed in Manufacturing Refresh PCOM 5.9.6.0
Temporary fix
Comments
APAR Information
APAR number
IC64204
Reported component name
PCOMM V5 COMBO-
Reported component ID
5639I700J
Reported release
590
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-10-28
Closed date
2009-11-02
Last modified date
2009-12-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSWLIB
Fix information
Fixed component name
PCOMM V5 COMBO-
Fixed component ID
5639I7000