APAR status
Closed as program error.
Error description
In Graphical Assignment (GA) when an assignment is made to a Labor whose Craft/Skill does not match that of the original Planned Labor record the bar should turn Red right away but instead it stays Teal colored. Presently as long as the assignment is still selected (has the dashed lines surrounding it) it stays Teal and only changes to Red when you click away from the bar to un-select it. This should be changed to as soon as the assignment bar is released on the mismatched Labor row it should turn Red. This change should apply to all validation colors such as green or yellow. STEPS TO REPRODUCE: 1. Create a new Labor and assign it only to Craft Elect. Put it on Calendar = DAY and Shift = DAY. 2. Create a new WO with Duration = 5 and give it Planned Labor of one Elect and one Mech. 3. Create a new Work List in GA. Calendar = DAY and Shift = DAY (make sure Calendar = DAY has an End Date of the end of the year and has the DAY shift applied for its entire length). 4. Give the new Work List a Start Date of the first of whatever the next month is. 5. Create a Work Query to select the new WO created above. 6. Save. Click on the Assignment View tab. 7. Click on the MECH Assignment on the Assignment tab 8. The Labor of matching Skills will highlight and the new Labor added above should not highlight as it is only Elect. 9. Drag the MECH assignment down to the non-hightlighted ELECT row of the new Labor. 10. It will stay Teal colored even when you finish dragging it. It will turn RED only when you click somewhere else to un-select that assignment. CURRENT ERRONEOUS RESULT: The bar stays Teal colored when you release it. It should turn Red at that point so you know right away that you have a mismatch. It will turn Red when click somewhere else but that may not be noticeable by the user, turning Red immediately is the expected behavior. EXPECTED RESULT: To turn the assignment bar Red immediately upon finishing the drag. ENVIRONMENT (SYSTEM INFO): Reproduced on all versions of Scheduler including 7.6.0.9 with current IFix and 7.6.1.0
Local fix
(none)
Problem summary
**************************************************************** * USERS AFFECTED: * * Scheduler users * **************************************************************** * PROBLEM DESCRIPTION: * * Bars are not updated immediately after dropping, so * * validations are not known until user selects some other part * * of the Gantt. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fixed
Temporary fix
Comments
APAR Information
APAR number
IJ06932
Reported component name
MAXIMO SCHEDULE
Reported component ID
5724R46SE
Reported release
767
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-06-07
Closed date
2018-06-21
Last modified date
2018-06-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MAXIMO SCHEDULE
Fixed component ID
5724R46SE
Applicable component levels
R767 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9NUN","label":"Maximo Asset Management Scheduler"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"767","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]