Error description
TADDM 7.3 FP3 - CONFIGURATION Tab missing (under Details view) for a successfully discovered F5 Big-IP device, after applying APARs: IV93358 IV97493 IJ03870
Local fix
Problem summary
CONFIGURATION Tab missing (under Details view) after a successful discovery of Big-IP F5 device. This problem occurs due to lack of synchronization between sensors while storing data. While running BigIPSnmp discovery, it is observed that whenever the order of storing model objects created by SnmpMib2 sensor and BigIPSnmp sensor is not correct, it results in random issues like config tab missing, storage error and sometimes both.
Problem conclusion
The fix for this APAR is contained in the following maintenance packages: | Fix Pack | 7.3.0-TIV-ITADDM-FP0005
Temporary fix
Comments
APAR Information
APAR number
IJ03885
Reported component name
APP DEPENDENCY
Reported component ID
5724N5500
Reported release
730
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-02-06
Closed date
2018-04-20
Last modified date
2018-04-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
999
Fix information
Fixed component name
APP DEPENDENCY
Fixed component ID
5724N5500
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSPLFC","label":"Tivoli Application Dependency Discovery Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"730","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
20 April 2018