Error description
Multiple Token nodes when Node1 goes down The cluster needs to be recycled causing a full outage for a while. there is a problem in checking if there is any active node already has token, the query should include constrain that TOKEN=1
Local fix
cluster recycle
Problem summary
USERS AFFECTED: ALL PROBLEM DESCRIPTION: MULTIPLE TOKEN NODES WHEN NODE1 GETS OOM AND IS NOT RESPONDING PLATFORMS AFFECTED : ALL
Problem conclusion
RESOLUTION SUMMARY: THIS MULTIPLE TOKEN NODES ISSUE IS A TIMING ISSUE. THE FIX INCLUDES: 1. HAVE A LOCK WHEN HEART BEAT THREAD UPDATES DATABASE TO CLEAN TOKEN NODE AND TAKES TOKEN FOR CURRENT NODE, SO WE DON'T HAVE TWO NODES TAKING THE TOKEN AT THE SAME TIME. 2. UPDATE TO MAKE SURE NO ACTIVE NODE HAS THE TOKEN BEFORE TAKING THE TOKEN FOR CURRENT NODE. THESE CHANGE ENSURES ONLY ONE NODE TAKES TOKEN WHEN A NODE GOES DOWN. DELIVERED IN: 5020500_1
Temporary fix
Fix the multiple token issue in ops server
Comments
APAR Information
APAR number
IC99032
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
524
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-01-28
Closed date
2015-01-22
Last modified date
2015-10-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
R525 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.4","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
29 October 2015