Error description
Consider two Business Processes - PNNBIRGMAOutboundTranslationWITHBIRGMAIDS and PNNBIRGMAOutboundTranslationWITHTESTIDS with EDI encoder service populating the Sender ID, Receiver ID and Accepterlookupalias. The Sender ID and Accepterlookup alias values are same but the Receiver ID value is different. There is one more business process PNN_Envelope_Queue1 with EDI Envelope serice in deferred mode. All the required envelopes are also created. First, execute PNNBIRGMAOutboundTranslationWITHBIRGMAIDS and PNNBIRGMAOutboundTranslationWITHTESTIDS with two different input files. Later, execute PNN_Envelope_Queue1, which creates two different output files with one ISA, one GS and one ST each. The parameters in the EDI Encoder service of the business processes are updated. Tried to execute expecting one ISA, two GS with different Receiver IDs and with one ST in each GS. But, the system creates one ISA, one GS with same Receiver ID (ID picked from the BP which ran second) with two STs. <assign to="enveloping.encode_by_outer_envelope.standards">X12</assign> <assign to="enveloping.use_new_key_convention.standards">X12</assign> The property parameter enveloping.encode_by_outer_envelope.standards=X12 in enveloping.properties is updated. Tried to execute expecting one ISA, two GS with different Receiver IDs and with one ST in each GS. But the system creates one ISA, two GS with same Receiver ID (Id picked from the BP which ran second) with two STs.
Local fix
STRRTC - 408922 UP / UP Circumvention: None No workaround available
Problem summary
Users Affected: All standards enveloping, translation and mapping users Problem Description: UNABLE TO GENERATE OUTBOUND X12 ISA INTERCHANGE CONTAINING SEVERAL GS MESSAGES HAVING DISTINCT GS RECEIVER IDs Platforms Affected: All
Problem conclusion
Resolution Summary: A code fix has been provided. Delivered In: 5020600 5020500_12 5105 5020601_7
Temporary fix
Comments
APAR Information
APAR number
IC98930
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-01-23
Closed date
2015-10-23
Last modified date
2017-03-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
ENVELOPE
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
R526 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
08 March 2017