Closed as program error.
Error description
Multiple SSL closures at the same time might cause the appliance not to respond temporarily to any traffic. For example, all transactions and user interaction might stall for several seconds. When this issue occurs: 1. A message similar to this appears in the log: [A-SERVICE][ssl][error] sslproxy(SSL-PROXY): tid(377228278)[1.2.3.4]: Timed out while waiting to finish sending of partially sent SSL closure alert 2. There is a gap in the logs of several seconds with no messages logged, followed by a flurry of activity as the appliance is trying to "catch up".
Local fix
Problem summary
Affected is the use of SSL with DataPower. SSL connection shutdown might cause a DataPower appliance to stall.
Problem conclusion
Fix is available in 5.0.0.13, 6.0.0.5 and 6.0.1.1. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC98330
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-12-13
Closed date
2014-02-19
Last modified date
2014-03-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R500 PSY
UP
R600 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
11 February 2022