Fixes are available
APAR status
Closed as program error.
Error description
Attempting to use excessive concat() arguments (over 800 parameters) might cause an unexpected restart of the DataPower appliance.
Local fix
Split up the concat into multiple variables, e.g. have half of the concat arguments assigned to variable1 and the rest assigned to variable2 Then concatenate variable1 and variable2. Keep each variable to 200 or fewer arguments.
Problem summary
Affected is the use of XPATH concat() function with a huge number of arguments. Compiling a stylesheet with a really huge number of arguments (seen with more than 800, but might happen with more than 200) might restart the DataPower appliance.
Problem conclusion
Fix is available in 5.0.0.11 and 6.0.0.3. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC95557
Reported component name
DTPWR INTGRAPL
Reported component ID
DP905XI52
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-08-28
Closed date
2013-10-21
Last modified date
2013-11-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DTPWR INTGRAPL
Fixed component ID
DP905XI52
Applicable component levels
R500 PSY
UP
R600 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSHT9H","label":"WebSphere DataPower Integration Appliance XI52"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]