Fixes are available
APAR status
Closed as program error.
Error description
When a user restarts an application domain before the domain is fully initialized from a previous restart domain request or after a restart of the appliance, the newly restarted domain might hang. The CLI or WebGUI interface from which the request to restart the domain was made might not return control to the user.
Local fix
Wait until the appliance is fully initialized (in the case of a full restart), or the domain is fully initialized (in the case of domain restart), before trying another domain restart of the affected domain. The use of Domain Availability can indicate when a domain is fully initialized, and can therefore be restarted.
Problem summary
Administrators who restart an application domain before the domain is fully initialized after a previous restart domain request or after restarting the appliance, might see the request hang on either the CLI or WebGUI.
Problem conclusion
Fix is available in 6.0.0.1. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC94536
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-07-31
Closed date
2013-08-08
Last modified date
2013-08-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R600 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
11 February 2022