Fixes are available
APAR status
Closed as program error.
Error description
Problem description: If the Throttle feature is set to Throttle or Terminate for the Temp File Space, and the monitored free space goes below one of the thresholds, the DataPower appliance will restart and, in the process, might erase data on an attached persistent storage (e.g. the RAID disk).
Local fix
Workarounds: Do not throttle on the Temp File Space.
Problem summary
Affected are all DataPower appliances configured to use a persistent storage such as internal RAID or CompactFlash or external iSCSI or NFS. If the Throttle is set to monitor the Temporary filesystem and to restart when the space is low, at the moment this condition is met, the DataPower appliance might erase the attached persistent storage(s) in the restart process.
Problem conclusion
Fix is available in 4.0.2.15, 5.0.0.10 and 6.0.0.2. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC93907
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-07-08
Closed date
2013-08-30
Last modified date
2013-09-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R402 PSY
UP
R500 PSY
UP
R600 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: