Fixes are available
APAR status
Closed as fixed if next.
Error description
When a username token (UNT) is already present in a request message and the AAA PostProcessing step is configured to replace the existing UNT, DataPower will replace it by creating an entirely new security header. In the event the existing UNT contained a Timestamp element, the Timestamp element would be removed as result of the new security header added by DataPower. This could then cause the backend server to fail the request due to the missing Timestamp element that it expected. DataPower should only replace the UNT element and not the entire security header.
Local fix
In the AAA PostProcessing step, set "Replace existing username token" to Off, to prevent the TimeStamp element from being overwritten with a new security header.
Problem summary
Fix will be available in a future major release.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
IC91903
Reported component name
DTAPWR B2B APL
Reported component ID
DP905XB62
Reported release
500
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-04-26
Closed date
2013-05-15
Last modified date
2013-05-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
R400 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSHTED","label":"WebSphere DataPower B2B Appliance XB62"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
15 May 2013