Error description
This issue was detected in email notifications. Where the name of the Consumer file should be populated, it contains the word "none." A reveiw of Process Data generated by the FileGatewayEventEmailNotification BP shows that the ConsumerFilename node contains the word "none." <ConsumerFilename>None</ConsumerFilename> This issue occurs on events codes that denote failures and also on ones that denote successes. FG_0415 Route Complete FG_0419 Delivery Complete FG_0456 Route Failed FG_0457 Delivery Failed
Local fix
STRTC 362974 SC / SC Circumvention: None
Problem summary
Users Affected: All Sterling File Gateway users Problem Description: Several Event codes do not receive/generate the name of Consumer file (ConsumerFilename). This was found in the email notifications. Where the name of the Consumer file should be populated it contains the word "none." A reveiw of Process Data generated by the FileGatewayEventEmailNotification BP shows that the ConsumerFilename node contains the word "none." <ConsumerFilename>None</ConsumerFilename> This issue occurs on events codes that denote failures and also on ones that denote successes. FG_0415 Route Complete FG_0419 Delivery Complete FG_0456 Route Failed FG_0457 Delivery Failed Platforms Affected: All
Problem conclusion
Resolution Summary: A code fix has been provided. Delivered In: 5020600 5020500_10 5105
Temporary fix
Comments
APAR Information
APAR number
IC91357
Reported component name
STR FILE GATEWA
Reported component ID
5725D0700
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-04-04
Closed date
2015-10-28
Last modified date
2016-03-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR FILE GATEWA
Fixed component ID
5725D0700
Applicable component levels
R226 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS4TGX","label":"IBM Sterling File Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]