Fixes are available
APAR status
Closed as program error.
Error description
Data Xfer from IBM i to PC, the system name is displayed as blank with EE connection. It is possible to select the system name form pull-down menu. Telnet and IEEE802.2 connection, it is displayed as correctly.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of Data Transfer * **************************************************************** * PROBLEM DESCRIPTION: When using Data Transfer with Enterprise* * Extender connection, the System Name * * list is empty. * **************************************************************** * RECOMENDATION: * **************************************************************** When using Data Transfer with a EE connection, the System Name list is empty. If the user selects the drop down list, the System Name appears at the 2nd postion, but the 1st position is empty. This error does not occur when using a LLC2 or TCP/IP connection.
Problem conclusion
PCSFT5.EXE has been changed to correct the Data Transfer drop down list. In a conditional statement for SNA connections, if the select System Name combo box fails, the return code is negative and it causes this problem. The solution is to not perform the combo box selection function when the default System Name is empty and the return code for checking the combo box selection needs to be initialized. . Fix scheduled for PCOM 6.0.8 Refresh Pack
Temporary fix
Comments
APAR Information
APAR number
IC90469
Reported component name
PCOMM V5 COMBO-
Reported component ID
5639I700J
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-02-26
Closed date
2013-02-27
Last modified date
2013-02-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSFT5
Fix information
Fixed component name
PCOMM V5 COMBO-
Fixed component ID
5639I700J
Applicable component levels
R605 PSN
UP
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSEQ5Y","label":"Personal Communications"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]