APAR status
Closed as program error.
Error description
A partner re-sent the ebMS ACK after DataPower re-sent an ebMS Message. Even though the partner re-sent the ebMS ACK toward the original ebMS Message, DataPower recognized this ebMS ACK as "Digest not match the original message".
Local fix
Problem summary
Affected are DataPower B2B Appliance customers resending an ebMS2 outbound message with signed ebMS2 acknoledgement requested. The modification of <eb:Timestamp> and <eb:TimeToLive> elements of an outbound re-sent ebMS2 message causes mismatch of digest value when receiving signed ebMS2 ACK from partners. The DataPower B2B Appliance modifies the content of <eb:Timestamp> and <eb:TimeToLive> elements which is not consistent with ebMS2 specification 2.0.
Problem conclusion
The fix is available in 4.0.1.16, 4.0.2.12 and 5.0.0.6 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC89244
Reported component name
DTAPWR B2B APL
Reported component ID
DP905XB62
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-12-20
Closed date
2013-02-27
Last modified date
2013-03-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DTAPWR B2B APL
Fixed component ID
DP905XB62
Applicable component levels
R401 PSY
UP
R402 PSY
UP
R500 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSHTED","label":"WebSphere DataPower B2B Appliance XB62"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
19 March 2013