Fixes are available
APAR status
Closed as program error.
Error description
When using WebSphere MQ .Net application with client automatic reconnection enabled, after a broken connection a NullReferenceException is thrown during a reconnection attempt. XMS trace shows NullReferenceException is thrown from Reconnect method: [16/11/2012 20:40:57:339933 ] 00000011 d UOW= source=IBM.WMQ.Nmqi.MQManagedReconnectableThread Exception in method Run() [16/11/2012 20:40:57:339933 ] 00000011 X UOW= source=IBM.WMQ.Nmqi.MQManagedReconnectableThread System.NullReferenceException: Object reference not set to an instance of an object. at IBM.WMQ.Nmqi.MQManagedReconnectableThread.Reconnect (ManagedHconn remoteHconn) at IBM.WMQ.Nmqi.MQManagedReconnectableThread.Run() [16/11/2012 20:40:57:371183 ] 00000011 > UOW= source=IBM.WMQ.Nmqi.MQManagedReconnectableThread method=FFST(String,string,string,uint,uint,MQULONG,MQULONG, ushort)
Local fix
Problem summary
**************************************************************** USERS AFFECTED: This issue affects users of the WebSphere MQ .Net application where client automatic reconnect functionality has been enabled. Platforms affected: Windows **************************************************************** PROBLEM SUMMARY: When WebSphere MQ .Net application is enabled with client automatic reconnection and a remote connection has been broken before any asynchronous messaging had occurred, waking the dispatcher thread that handles asynchronous message consumption results in NullReferenceException as this thread would not have been created.
Problem conclusion
The code has been altered to ensure the asynchronous message consume dispatch thread has been created prior to the broken connect, waking it only in the case it exists. This change prevents the NullReferenceException from occurring. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: v7.1 Platform Fix Pack 7.1.0.3 -------- -------------------- Windows 7.1.0.3 Platform v7.5 -------- -------------------- Multiplatforms 7.5.0.1 The latest available maintenance can be obtained from 'WebSphere MQ Recommended Fixes' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037 If the maintenance level is not yet available information on its planned availability can be found in 'WebSphere MQ Planned Maintenance Release Dates' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IC88691
Reported component name
WMQ WINDOWS V7
Reported component ID
5724H7220
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-11-28
Closed date
2012-11-30
Last modified date
2012-11-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WMQ WINDOWS V7
Fixed component ID
5724H7220
Applicable component levels
R710 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDEZSF","label":"IBM WebSphere MQ Managed File Transfer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]