APAR status
Closed as program error.
Error description
The following error can occur in the Tivoli Storage Manager actlog after an I/O error was reported from the IBM device driver in the system log: ANR9999D_2697328974 CheckPosition(pvrntp.c:xxxx) Thread<XXX>: NtpOpReadBlockID: failed on volume XXXXXXXX drive XXX (/dev/xxx) error 1. error 1 means I/O error. This does not necessarily mean that the volume was positioned wrong. For more information review the system log or tape drive diagnostics to see what the I/O error was. The system log under - AIX is the error report (errpt) - Linux is the file /var/log/messages - Windows is the eventlog In this case, a more meaningful message (instead of ANR9999D_2697328974 CheckPosition) would have been: ANR8302E I/O error on drive drive name with volume volume name (OP=internal code, Error Number=internal code, CC=internal code, rc = return code, KEY= internal code, ASC=internal code, ASCQ= internal code, SENSE=sense data, Description=error description). Refer to the Tivoli Storage Manager documentation on I/O error code descriptions. Customer/L2 Diagnostics Example from /var/log/messages from a Linux system: Aug 2 05:44:36 xxxxx lin_taped[1856]: lin_taped: beginning failover for IBMtapeXXX, hba x, channel 0, id xx, lun xx Aug 2 05:44:36 xxxxx lin_taped[1856]: wake up device IBMtapeXXX with result -1 Aug 2 05:44:36 xxxxx kernel: [5857767.456675] lin_tape: IBMtapeXXX failover failed. Tivoli Storage Manager Versions Affected: Tivoli Storage Manager server versions 5.5, 6,1, 6.2 and 6.3 Initial Impact: Low Additional Keywords: zz61 zz62 zz63 TSM message block
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Tivoli Storage Manager server users. * **************************************************************** * PROBLEM DESCRIPTION: See error description. * **************************************************************** * RECOMMENDATION: Apply fixing level when available. This * * problem is currently projected to be fixed * * in levels 6.2.5 and 6.3.3. Note that this is * * * * subject to change at the discretion of IBM. * **************************************************************** *
Problem conclusion
This problem was fixed. Affected platforms: AIX, HP-UX, Solaris, Linux, and Windows.
Temporary fix
Comments
APAR Information
APAR number
IC85865
Reported component name
TSM SERVER
Reported component ID
5698ISMSV
Reported release
62L
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-08-15
Closed date
2012-08-24
Last modified date
2012-08-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TSM SERVER
Fixed component ID
5698ISMSV
Applicable component levels
R62A PSY
UP
R62H PSY
UP
R62L PSY
UP
R62S PSY
UP
R62W PSY
UP
R63A PSY
UP
R63H PSY
UP
R63L PSY
UP
R63S PSY
UP
R63W PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"62L","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date: