APAR status
Closed as program error.
Error description
svc is marked as unknown if tpcr is unable to connect to it
Local fix
Problem summary
The SVC authentication username and password became out of sync with the TPC-R server and the attached devices. The two passwords for the source and target SVC's were asymettric therby compounding the issue. TPC-R was unable to query what type of device was connected because of the authentication failure thereby causing the connection type to be displayed as :"Unknown"
Problem conclusion
This problem was fixed in the code by not allowing an Unknown type to be surfaced and instead if we cannot find the device type return the default type SVC.
Temporary fix
Comments
APAR Information
APAR number
IC82214
Reported component name
TPC FOR REPLICA
Reported component ID
5608TRM00
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-03-22
Closed date
2012-04-03
Last modified date
2012-04-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC FOR REPLICA
Fixed component ID
5608TRM00
Applicable component levels
R420 PSY
UP
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMN28","label":"Tivoli Storage Productivity Center for Replication"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]