A fix is available
APAR status
Closed as program error.
Error description
When using a Message Logger primitive a Null Pointer Exception will be thrown when a message is received to be logged that does not contain the SMO Header and Version information. This exception is not helpful in diagnosing the problem and makes no reference or mention to the missing headers. This prevents customer from correcting the issues. A more meaningful exception referencing the missing header will be thrown instead.
Local fix
N/A
Problem summary
**************************************************************** USERS AFFECTED: Users of WebSphere Enterprise Service Bus v7 and Business Process Server v7 and v8 who use mediation flows. **************************************************************** PROBLEM DESCRIPTION: The SMO Header section of the SMO is created when a new SMO is created. This can be removed by the user, such as in an XSL Transformation. If a SMO with no MessageUUID or Version is sent to a MessageLogger primitive or Trace primitive then a NullPointerException may be seen.
Problem conclusion
The code was changed such that the NullPointerException is avoided and instead an exception that shows the MessageUUID or Version are missing is thrown. These will need to be preserved by the user through any alteration to the SMO.
Temporary fix
Comments
APAR Information
APAR number
IC80873
Reported component name
WEB ESB FOR WIN
Reported component ID
5724I8200
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-01-19
Closed date
2014-11-13
Last modified date
2014-11-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEB ESB FOR WIN
Fixed component ID
5724I8200
Applicable component levels
R700 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7J6S","label":"WebSphere Enterprise Service Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]